Pressure Performance Tests KOENIG Expander®
Test (A) Pressure Test To Failure
In test (A) the KOENIG Expander® is subject to increasing static pressure until plug blowout occurs. These tests are done by Koenig Verbindungstechnik for functional testing during manufacturing runs. Each production lot (Batch No.) undergoes these tests.
Test (B) Temperature/Pressure Cycling
In test (B) the KOENIG Expander® is subject to a long term test simulating practical conditions. This determines the pressure which can be applied (lower limit) without plug blowout, with intermittent pressure and varying temperature.
Conditions
Temperature: 2 hours at +100 °C, 2 hours at -40 °C
series LK and LP partially 2 hours at +150 °C, 2 hours at -40 °CTemperature change: between 30 and 45 minutes Pressure: intermittent 2 minutes at 0 bar, 3 minutes at test pressure Duration: 170 h (long-term test) Drill Hole: tolerance, roundness and roughness per data sheets, plain surface distance from edge per data sheets
We emphasize the fact that the use of our sealing plugs has been tested in the above listed temperature range. Please contact us in case of deviating temperature conditions.